Open Access   Article Go Back

Smart Drip Using Arduino Microcontroller

Amal Ajayan1 , V Sheeja Kumari2 , Fathima Abdul Rahim3 , ooraj S4

Section:Research Paper, Product Type: Journal Paper
Volume-7 , Issue-6 , Page no. 822-829, Jun-2019

CrossRef-DOI:   https://doi.org/10.26438/ijcse/v7i6.822829

Online published on Jun 30, 2019

Copyright © Amal Ajayan, V Sheeja Kumari, Fathima Abdul Rahim, Sooraj S . This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

View this paper at   Google Scholar | DPI Digital Library

How to Cite this Paper

  • IEEE Citation
  • MLA Citation
  • APA Citation
  • BibTex Citation
  • RIS Citation

IEEE Style Citation: Amal Ajayan, V Sheeja Kumari, Fathima Abdul Rahim, Sooraj S, “Smart Drip Using Arduino Microcontroller,” International Journal of Computer Sciences and Engineering, Vol.7, Issue.6, pp.822-829, 2019.

MLA Style Citation: Amal Ajayan, V Sheeja Kumari, Fathima Abdul Rahim, Sooraj S "Smart Drip Using Arduino Microcontroller." International Journal of Computer Sciences and Engineering 7.6 (2019): 822-829.

APA Style Citation: Amal Ajayan, V Sheeja Kumari, Fathima Abdul Rahim, Sooraj S, (2019). Smart Drip Using Arduino Microcontroller. International Journal of Computer Sciences and Engineering, 7(6), 822-829.

BibTex Style Citation:
@article{Ajayan_2019,
author = {Amal Ajayan, V Sheeja Kumari, Fathima Abdul Rahim, Sooraj S},
title = {Smart Drip Using Arduino Microcontroller},
journal = {International Journal of Computer Sciences and Engineering},
issue_date = {6 2019},
volume = {7},
Issue = {6},
month = {6},
year = {2019},
issn = {2347-2693},
pages = {822-829},
url = {https://www.ijcseonline.org/full_paper_view.php?paper_id=4637},
doi = {https://doi.org/10.26438/ijcse/v7i6.822829}
publisher = {IJCSE, Indore, INDIA},
}

RIS Style Citation:
TY - JOUR
DO = {https://doi.org/10.26438/ijcse/v7i6.822829}
UR - https://www.ijcseonline.org/full_paper_view.php?paper_id=4637
TI - Smart Drip Using Arduino Microcontroller
T2 - International Journal of Computer Sciences and Engineering
AU - Amal Ajayan, V Sheeja Kumari, Fathima Abdul Rahim, Sooraj S
PY - 2019
DA - 2019/06/30
PB - IJCSE, Indore, INDIA
SP - 822-829
IS - 6
VL - 7
SN - 2347-2693
ER -

VIEWS PDF XML
398 193 downloads 113 downloads
  
  
           

Abstract

During recent years due to the technological advancements many sophisticated techniques has been evolved for assuring fast recovery of the patients in hospitals. For good patient care in hospitals, assessment and management of patient’s fluid in the drip is the most fundamental thing required. All most in all hospital, an assist/nurse is responsible for monitoring the fluid level continuously. But in the government hospitals due to the unavailability of enough number of nurses, observing this fluid is a great headache to the hospitals. Our smart drip using Arduino microcontroller will overcome the complications like infiltration, hematoma, air embolism, blood backup in tubing, extra vascular Injection, Intra-arterial Injection etc. It will detect the emptying of drip bag with the help of Ultrasonic sensor. To overcome this critical situation, we develop a smart drip using arduino with automatic alerting and indicating system is proposed where Ultrasonic sensor is used as a level sensor. Whenever the fluid becomes low, it will send an alert message to the nurse rooms and also nurses can monitor the LIVE level graph in their computer. This technology reduces the work of the nurse rather than keep on looking of an IV Fluid system. one of the best advantages of our project is that the ease interface with users that functionally can be managed by means of an alert message.

Key-Words / Index Term

Arduino Microcontroller, Ultrasonic Sensor, Drip

References

[1] R.Vasuki, Dennis, HemPriya Changer, “An portable monitoring device of measuring drips rate by using an Intravenous (IV) set”, International Journal of Biotechnology Trends and Technology Vol. 1, Issue 3, No.4 2011.
[2] C.C.Gavimath, Krishnamurthy Bhat, C.C.Chayalakshmi, R.S.Hooli, B.E.Ravishankera “Design and Development of versatile saline flow rate measuring system and GSM based remote monitoring device”, International Journal Of Pharmaceutical Applications ISSN 0976-2639.
[3] R.Aravind, Syed Mustak Ahmed “Design of family health monitoring system using wireless communication”, International Journal of Advanced Research in Computer and Communication Engineering Vol. 2, Issue 9, September 2013 [4] V.Ramya, B.Palaniappan, Anuradha Kumari “Embedded patient monitoring system” International Journal of Embedded Systems and Applications (IJESA) Vol.1, No.2,
December 2011
[5] D.Janani, J.Prathibanandhi, P.Meenakshi Vidya, K.S.Sujatha “Wireless Saline Bottle Level Indicator for Hospitals”, Compo soft an International Journal of Advanced computer Technology.
[6] Nakajima K., Osa A., Maekawa T. and Mike H. [1997]. “Evaluation of Body Motion by Optical Flow Analysis”, Japan Journal of Applied Physics, 36(5A), Part 1, 2929- 2937. [7] Cyber-Physical Medical and Medication Systems by Albert M. K. Cheng, 2008.
[8] Zhou Xiao, Li Jiaming, Pu Junjia, Yang Zhi, “The Design and implement of Mobile Remote Medical Ward System.” 2010.

[9] Nivedita Daimiwal, DipaliRamdasi, RevathiShriram, AsmitaWakankar, “Wireless Transfusion Supervision and Analysis Using Embedded System”.
[10] . Hung, Orlando R., Peter H. Gregson, and David C. Roach. "Fluid monitoring device." U.S. Patent No. 7,327,273. 5 Feb. 2008.